Brand Name : VEIKONG

Model Number : VFD500-PV

Certification : CE

Place of Origin : China

MOQ : 1

Price : Negotiable

Payment Terms : L/C, T/T, Western Union

Supply Ability : 15000pcs per Month

Delivery Time : 3 days, depend on the order quantity

Packaging Details : the power less than 45kw use Carton, starting from 45kw use Wooden case

Product Name : 18.5kw 22kw inverter

Max inputDC voltage : 450vdc or 800v dc

Oem : available

Type : AC Inverter/Converter

Output frequency : 50Hz/60Hz

Display : LCD,LED

Contact Now

Solar pump inverter 18.5kw 22kw 220V single phase for agricultural irrigation

Key Advantages:

1. MPPT efficiency more than 99%.

2. Drives well all 1/3 phase AC pumps and PMSM in solar pumping system.
3. Voc of solar panel can set by manual or MPPT automatically tracking.
4. Solar DC & Grid AC power supply input both ok.
5. Dry run & Full water tank protection.
6. Short circuit, over load, over current... motor production.
7. The PQ (power/flow) performance curve enables calculating the flow output from the pump
8. Ambient temperature for using: -10 to +50˚C.
9. Inverter Power range: 220V, 0.75KW to 110KW. 380V/480V, 0.75KW to 250kw

Techincal Parameters:

1. Wake up and sleep function parameters:

P47.05 Light detection threshold If the output frequency is lower than this value and exceeds P47.06, it will be reported to Sleep and stop 0Hz
P47.06 Light detection time See P47.05 for explanation. 60s
P47.07 Light weak wake up time After the sleep fault is reported, if the time when Vdc is higher than the undervoltage point is greater than the set value, the fault state is exited and the operation continues. 600s

2. Dry runing protection function parameters:

P24.12 Dry run/Unload protection option

0: No offload detection is performed;

1: Enable dry run detection

1
P24.13 Dry run/Unload detection level

0.0 to 200.0%

The percentage of motor rated current.

0.0%
P24.14 Dry run Unload detection time 0.000s~60.000s 30.000s
P24.15 Unload detection offset frequency

0.00Hz~Fmax

Detection frequency=Fmax-P24.15

5.00Hz
P24.16 Reset time of dry run protection 0.0~6000.0 240.0s
P23.21 Dry run detection mode

0000:Coast stop

1000:Fast stop

3000:Continue to run

0000

3. Water full protection function parameters:

P47.18 Full water level detection channel

0:ineffective

1:AI1

2:AI2

3:AI3

4:AI4

Note: DI terminal function code 60-full water level detection is same with Analogue detection, and the detection time and recovery time are the same.

0
P47.19 Full water level detection value

0.0~100.0%

0.0%
P47.20 Full water level detection time

0.0~3000.0s

When DI-60 is valid or meets the analog detection channel greater than P47.19 and maintains P47.20 time, the system reports A.Full and stops.

10.0s
P47.21 Full water recovery time

0.0~3000.0s

When the condition described in P47.20 does not meet full water level detection requirement ,it will be returned to normal state after delay

10.0s

Support optional LCD keypad

18.5kw 22kw 220V Single Phase Solar Pump Inverter For Agricultural Irrigation

Support optional GPRS Module

18.5kw 22kw 220V Single Phase Solar Pump Inverter For Agricultural Irrigation

VEIKONG VFD500-PV 2.2KW 4KW picture:
18.5kw 22kw 220V Single Phase Solar Pump Inverter For Agricultural Irrigation

VEIKONG Solar pump special parameter User mode fast quick start

18.5kw 22kw 220V Single Phase Solar Pump Inverter For Agricultural Irrigation

VEIKONG Solar pump special parameter User mode fast quick start

Function code Name Description Default Property
47 Group solar pumping special group
P00.03 RESET

0:NO ACTION

11:Restore default parameter except for motor parameter and auto-tune related parameter and factory parameter

12:Restore default to factory parameter 13:Clear tripping record

0
P00.06 Source of the Operation Command

0:keypad

1:terminal

2:communication

Ø Command source: run,stop,forward,reverse,jog,fast brake stop.etc

0
P00.07 Numeric frequency setting 00.00Hz~maximum frequency 50.00Hz
P00.11 Application Macro

01:Output three phase 50HZ

02:Output three phase 60hz

21:Output single phase with capacitor 50hz

22:Output single phase with capacitor 60hz

31:Output single phase without capacitor 50hz

32:Output single phase without capacitor 60hz

00
P01.06 Maximum frequency 10.00~600.00Hz 50.00Hz
P01.08 Upper limit frequency Lower limit frequency-maximum frequency 50.00Hz
P07.03 Relay 1 Output terminal function group(T1A T1B T1C)

0:No function

1:READY

2:RUN

3:Error1(stop fault)

4:Error2(same as Error1 except undervoltage)

5:Warning output(fault but in running)

3
P11.01 AC asynchronous motor TYPE

0:Three phase AC asynchronous motor

1:Single phase AC asynchronous motor without starting capacitor

0
P11.02 Motor rated power

0.1kW~710.0kW

Ø when power is less than 1kw ,0.75kw set to 0.8 as per round up principle ,0.55kw motor set 0.6

Ø when change motor rated power,AC drive will automatically set other parameter of motor name plate and motor model parameter be careful to use

Depend
P11.03 Motor rated voltage 10V~2000V Depend
P11.04 Motor rated current

P11.02<30kW:0.01A

P11.02>=30kW:0.1A

Depend
P11.05 Motor rated frequency 1.00Hz~600.00Hz 50.00Hz
P11.06 Motor rated RPM 1~60000rpm Depend
P21.00 Monitoring display

0:Standard mode (display frequency only)

1:Automatic scrolling display(Check 3.1 in detail )it show hz,current,power and voltage

0


Product Tags:

18.5kw Single Phase Solar Pump Inverter

      

22kw Single Phase Solar Pump Inverter

      

18.5kw single phase solar pump controller

      
China 18.5kw 22kw 220V Single Phase Solar Pump Inverter For Agricultural Irrigation wholesale

18.5kw 22kw 220V Single Phase Solar Pump Inverter For Agricultural Irrigation Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shenzhen Veikong Electric Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)